Specifications Contactor Application: motor control Product Or Component Type: contactor Product Name: TeSys K Range: TeSys Device Application: control Device Short Name: LC1K Contractual warranty...



Specifications

  • Contactor Application: motor control
  • Product Or Component Type: contactor
  • Product Name: TeSys K
  • Range: TeSys
  • Device Application: control
  • Device Short Name: LC1K

Contractual warranty

  • Warranty: 18 months

Complementary

  • Minimum Switching Current: 5 mA signalling circuit
  • Mechanical Robustness: shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5…300 Hz IEC 60068-2-6
  • [Uc] Control Circuit Voltage: 24 V AC 50/60 Hz
  • [Ue] Rated Operational Voltage: power circuit 690 V AC 50/60 Hz || signalling circuit <= 690 V AC 50/60 Hz
  • Height: 58 mm
  • Average Impedance: 3 mOhm – Ith 16 A 50 Hz power circuit
  • Auxiliary Contact Composition: 1 NC
  • Control Circuit Voltage Limits: operational 0.8…1.15 Uc 50 C) || drop-out 0.2…0.75 Uc 50 C)
  • Non Overlap Distance: 0.5 mm
  • [Ith] Conventional Free Air Thermal Current: 16 A 50 C power circuit || 10 A 50 C signalling circuit
  • Mounting Support: printed circuit boards
  • Control Circuit Type: AC 50/60 Hz
  • Safety Reliability Level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Insulation Resistance: > 10 MOhm signalling circuit
  • Rated Breaking Capacity: 110 A 415 V IEC 60947 || 110 A 440 V IEC 60947 || 80 A 500 V IEC 60947 || 110 A 220…230 V IEC 60947 || 110 A 380…400 V IEC 60947 || 70 A 660…690 V IEC 60947
  • Irms Rated Making Capacity: 110 A AC power circuit NF C 63-110 || 110 A AC power circuit IEC 60947 || 110 A AC signalling circuit IEC 60947
  • Motor Power Kw: 1.5 kW 220…230 V AC 50/60 Hz AC-3 || 2.2 kW 380…415 V AC 50/60 Hz AC-3 || 3 kW 440 V AC 50/60 Hz AC-3 || 3 kW 480 V AC 50/60 Hz AC-3 || 3 kW 500…600 V AC 50/60 Hz AC-3 || 3 kW 660…690 V AC 50/60 Hz AC-3 || 1.5 kW 400 V AC 50/60 Hz AC-4 || 1.5 kW 220…230 V AC 50/60 Hz AC-3e || 2.2 kW 380…415 V AC 50/60 Hz AC-3e || 3 kW 440 V AC 50/60 Hz AC-3e || 3 kW 480 V AC 50/60 Hz AC-3e || 3 kW 500…600 V AC 50/60 Hz AC-3e || 3 kW 660…690 V AC 50/60 Hz AC-3e
  • Associated Fuse Rating: 25 A gG <= 440 V power circuit || 25 A aM power circuit || 10 A gG signalling circuit IEC 60947 || 10 A gG signalling circuit VDE 0660
  • Net Weight: 0.18 kg
  • [Uimp] Rated Impulse Withstand Voltage: 8 kV
  • Inrush Power In Va: 30-30 VA 20 C)
  • Connections – Terminals: solder pins 1.5 x 0.9 mm
  • Pole Contact Composition: 3 NO
  • Utilisation Category: AC-4 || AC-3 || AC-3e
  • [Ie] Rated Operational Current: 6 A<= 440 V AC AC-3 power circuit || 6 A<= 440 V AC AC-3e power circuit
  • Minimum Switching Voltage: 17 V signalling circuit
  • Maximum Operating Rate: 3600 cyc/h
  • Signalling Circuit Frequency: <= 400 Hz
  • Electrical Durability: 1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || AC
  • Mechanical Durability: 10 Mcycles
  • Auxiliary Contacts Type: instantaneous 1 NC
  • Poles Description: 3P
  • Hold-In Power Consumption In Va: 4.5-4.5 VA 20 C)
  • Operating Time: 10…20 ms coil de-energisation and NO opening || 10…20 ms coil energisation and NO closing
  • Width: 45 mm
  • Overvoltage Category: III
  • Depth: 57 mm
  • [Ui] Rated Insulation Voltage: power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
  • [Icw] Rated Short-Time Withstand Current: 90 A 50 C – 1 s power circuit || 85 A 50 C – 5 s power circuit || 80 A 50 C – 10 s power circuit || 60 A 50 C – 30 s power circuit || 45 A 50 C – 1 min power circuit || 40 A 50 C – 3 min power circuit || 20 A 50 C – >= 15 min power circuit || 80 A – 1 s signalling circuit || 90 A – 500 ms signalling circuit || 110 A – 100 ms signalling circuit
  • Heat Dissipation: 1.3-1.3 W

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP1503003EN
  • Sustainable Offer Status: Green Premium product
  • Toxic Heavy Metal Free: Yes
  • Reach Regulation: Free of Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Reach Free Of Svhc: Yes
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
  • Circularity Profile: ENVEOLI1503003EN
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
  • Standards: EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
  • Flame Retardance: V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
  • Ambient Air Temperature For Storage: -50-80 C
  • Protective Treatment: TC IEC 60068 || TC DIN 50016
  • Ip Degree Of Protection: IP2X VDE 0106
  • Operating Altitude: 6561.68 ft (2000 m) without derating

Downloads

Spec Sheet

CAD

TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-isometric (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-left (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_3D-simplified (stp)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-bottom (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-front (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-right (dxf)
IEC Contactor, 6-12A, 3 Pole, K-Line, Solder Pin Terminals – E0210201-01 (dwg)
IEC Contactor, 6-12A, 3 Pole, K-Line, Solder Pin Terminals – E0210201-01 (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-back (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-isometric (dwg)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-right (dwg)
LC1K06015B7_CAD_DOC – LC1K06015B7_2D+Front+View (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-front (dwg)
LC1K06015B7_CAD_DOC – LC1K06015B7_3D (stp)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-bottom (dwg)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-left (dwg)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-top (dwg)
LC1K06015B7_CAD_DOC – LC1K06015B7_2D+Right+Side+View (dwg)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-back (dwg)
LC1K06015B7_CAD_DOC – LC1K06015B7_2D+Front+View (dwg)
LC1K06015B7_CAD_DOC – LC1K06015B7_2D+Right+Side+View (dxf)
TeSys k – CONTACTOR SPRING – 3D CAD – MCADPP0003355_2D-top (dxf)

Instruction sheet

LC1-K contactor – Instruction Sheet – 1378085_01A55_15 (pdf)

Certificate

CB Certificate TeSys K_LC.K_LP.K – LC.K_LP.K_Le+Vaudreuil_Batam_CN51561-A1_M1 (pdf)
CSA Certificate_ TeSys K_LC.K_LP.K_CA.KN_CAK_LA1KN_LA4K – COFC_80120004_EN (pdf)
UL_Certificate_TeSys K_LC1K_LC7K – E48539-19930706-CertificateofCompliance (pdf)

Technical Drawing

LC1K06015B7_2DSalesDrawing_PDF – LC1K06015B7_2D+Sales+Drawing (pdf)

Environmental Disclosure

PEP_TeSys LC1K09-K16 – PEP+ecopassport+SCHN-2015-025-EN_1 (pdf)

Declaration of conformity

EU_Declaration_TeSysK_LC.K&LP.K06-16 – PP_EU_Doc_LC_K_LP_K06-16_SC16040406E.docx (pdf)
UKCA Declaration TeSys K_LC.K,LP.K – UK_Doc_LC_K_LP_K06-16_SC16040406A-UK.docx (pdf)

Circularity Profile

Eoli_Contactors, TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NO aux. – 220…230 V AC coil – EoLI_ENVEOLI1503003_1 (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Add a Review