Shopping Cart

Motor controller, TeSys T, Motor Management, CANopen, 6 logic inputs, 3 relay logic outputs, 5 to 100A, 24VDC

Original price was: $906.53.Current price is: $149.00.


Specifications Product Or Component Type: motor controller Product Name: TeSys T Measurement Current: 5-100 A Range: TeSys Current Consumption: 56...127 mA [Us] Rated Supply Voltage:...



Specifications

  • Product Or Component Type: motor controller
  • Product Name: TeSys T
  • Measurement Current: 5-100 A
  • Range: TeSys
  • Current Consumption: 56…127 mA
  • [Us] Rated Supply Voltage: 24 V DC
  • Communication Port Protocol: CANopen
  • Bus Type: CANopen ISO 1198 1…127 10…1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable || CANopen ISO 1198 1…127 10…1000 kbit/s, terminal block 4 twisted shielded pairs cable
  • Supply Voltage Limits: 20.4-26.24 V DC
  • Device Application: equipment monitoring and control
  • Device Short Name: LTMR

Contractual warranty

  • Warranty: 18 months

Complementary

  • Contacts Type And Composition: 1 NO + 1 NC fault signal || 3 NO
  • Height: 61 mm
  • Connection Pitch: 5.08 mm
  • Permissible Power: 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Network And Machine Diagnosis Type: motor control command recording || trip context information || starting current and time || event recording || fault recording || remaining operating time before overload tripping || phase fault and earth fault trip counters || waiting time after overload tripping || running hours counter/operating time || trip history information
  • Pollution Degree: 3
  • Logic Input Number: 6
  • Maximum Operating Rate: 1800 cyc/h
  • Connections – Terminals: control circuit connector 1 0.25-2.5 mm AWG 24…AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm AWG 24…AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm AWG 24…AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm AWG 24…AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm AWG 24…AWG 14)solid without cable end
  • Input Current: 7 mA
  • Current State 1 Guaranteed: logic input < 15 V 2…15 mA 15 ms
  • Net Weight: 0.53 kg
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
  • Associated Fuse Rating: 4 A gG output || 0.5 A gG control circuit
  • Electromagnetic Compatibility: electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
  • Measurement Accuracy: 5…15 % earth fault current internal measurement || 1 % voltage 100…830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
  • Current State 0 Guaranteed: logic input < 5 V <= 15 mA 5 ms
  • [Ui] Rated Insulation Voltage: 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
  • Short-Circuit Withstand: 100 kA conforming to EN/IEC 60947-4-1
  • Compatibility Code: LTMR
  • Protection Type: thermal protection || reverse polarity protection || phase unbalance || phase failure || overload (long time) || thermal overload protection || load fluctuation || power factor variation || earth-leakage protection || locked rotor || overload
  • Web Services: web server
  • Width: 91 mm
  • Load Current: 5 A 250 V AC logic output || 5 A 30 V DC logic output
  • Tightening Torque: control circuit 0.5-0.6 N.m flat 3 mm
  • Overvoltage Category: III
  • Depth: 122.5 mm
  • Maximum Operating Frequency: 2 Hz
  • Metering Type: imbalance current || earth-fault current || temperature || phase current I1, I2, I3 RMS || average current Iavg

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP060308EN_V2
  • Sustainable Offer Status: Green Premium product
  • Pvc Free: Yes
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI100411EN_V2
  • Eu Rohs Directive: Compliant
  • Halogen Content Performance: Halogen free plastic parts product

Environment

  • Product Certifications: CCC || C-tick || ABS || RINA || KERI || EAC || ATEX || UL || NOM || RMRoS || LROS (Lloyds register of shipping) || CSA || GL || BV || DNV
  • Mechanical Robustness: vibrations mounted on symmetrical rail1 Gn, 5…300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5…300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
  • Ambient Air Temperature For Operation: -20-60 C
  • Standards: IACS E10 || CSA C22.2 No 14 || UL 508 || IEC 60947-4-1 || EN 60947-4-1
  • Ambient Air Temperature For Storage: -40-80 C
  • Protective Treatment: 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
  • Operating Altitude: <= 6561.68 ft (2000 m) without derating
  • Fire Resistance: 650 C EN/IEC 60695-2-12 || 960 C UL 94
  • Ip Degree Of Protection: IP20

Downloads

Spec Sheet

Brochure

TeSys T Motor Management System Brochure – 8502BR1602 (pdf)
Industrial Automation and Control Product Lines Brochure – 998-20256927_2019_Line_Card_GM (pdf)

User guide

TeSys DFB Library V2 for Unity Pro – User Manual – 1672609EN-03 (pdf)
TeSys T DTM for FDT Container Online Help – 1672614EN_02 (pdf)
TeSys Firmware Update Utility (LTMR and LTMCU) User Guide – 8536IB1915 (pdf)
TeSys T – Use in Explosive Atmospheres – 1672602-06 (pdf)
TeSys T LTMR Motor Management Controller Installation Guide – DOCA0128EN-02 (pdf)

Software – Release

Firmware Upgrade Tools – TeSys_Programmer_V3.1.000.zip
Firmware Upgrade Tools – TeSys_Programmer_V3.1.000_hash.txt

CAD

TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-isometric (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-left (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-back (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-left (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-back (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-right (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-top (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694 (pdf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-front (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-right (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-bottom (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-isometric (dxf)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-front (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-bottom (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_2D-top (dwg)
TeSys T – Motor controller LTMR TeSys T – 24 V DC 8 A for CANopen – 3D CAD – MCADPD0004694_3D-simplified (stp)

Firmware

TeSys T Firmware 2.9 for LTMR Ethernet & 2.7 for LTMR Profibus – Evo_TeSysT_Pack-15_hash.txt
TeSys T Firmware 2.9 for LTMR Ethernet & 2.7 for LTMR Profibus – Evo_TeSysT_Pack-15.zip
TeSys T Firmware 2.9 for LTMR Ethernet & 2.7 for LTMR Profibus – TeSysT_Pack-15_ReleaseNotes (pdf)

Catalog

Digest Catalog 16: NEMA and Definite Purpose Contactors and Starters (SEP 2022) – 0100CT1901_SEC-16_SEP2022 (pdf)
TeSys catalogue – 2020 – chapter C1 Motor management systems TeSys LUTM, T – C1+-+Motor+management+systems_EN+(web) (pdf)

Circularity Profile

End-of-Life Instructions TeSys T – ENVEOLI100411EN_V2 (pdf)

Environmental Disclosure

Motor management system – ENVPEP060308EN_V02.01-EN (pdf)

Instruction sheet

TeSys T – LTM R Motor management controller – Instruction sheet – AAV7709901-08 (pdf)
AC Magnetic Starters with TeSys T MMS, Size 1 Instructions – 30072-452-66_Rev.01 (pdf)

Declaration of conformity

EU_Declaration_SC16040410D_TeSys_LTMR-LTMEV-LTM9F – M_EU_declaration_of_conformity_SC16040410D (pdf)

Certificate

CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 – TeSysT-LTMR-LTMEV_FR659184@ (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Videos

Replacing DC Coil on a TeSys D Series Contactor | Schneider Electric Support Replacing AC Coil on a TeSys D Series Contactor | Schneider Electric Support Resetting TeSys T Normally Closed Contacts by Exiting Config Mode | Schneider Electric Support Switching from Modbus TCP to IP Communication on TeSys T Controllers | Schneider Electric Support Configuring IP Address for TeSys T Controller in SoMove | Schneider Electric Support Disabling Network Connectivity on TeSys T Motor Management System | Schneider Electric Support Resetting a LTMR TeSys T Module Back to Factory Defaults Locally | Schneider Electric Support Connecting TeSys T Controller to SoMove via Modbus Serial | Schneider Electric Support

Add a Review

Your email address will not be published. Required fields are marked *

Related Products