Shopping Cart

soft starter for asynchronous motor, Altistart 01, ATS01, 3A, 110…480V, 0.55…1.1kW

Original price was: $130.68.Current price is: $65.34.


Specifications Current Consumption: 15 A at nominal load Product Destination: asynchronous motors Range Of Product: Altistart 01 Product Or Component Type: soft starter Motor Power...



Specifications

  • Current Consumption: 15 A at nominal load
  • Product Destination: asynchronous motors
  • Range Of Product: Altistart 01
  • Product Or Component Type: soft starter
  • Motor Power Kw: 0.37 kW, 3 phase 230 V || 0.55 kW, 3 phase 230 V || 1.1 kW, 3 phase 400 V || 0.37 kW, 1 phase 230 V
  • Phase: 1 phase
  • Power Dissipation In W: 19 W in transient state || 4 W at full load and at end of starting
  • Utilisation Category: AC-53B EN/IEC 60947-4-2
  • Icl Starter Rating: 3 A
  • Type Of Start: start with voltage ramp
  • [Us] Rated Supply Voltage: 110…480 V – 10…10 %
  • Product Specific Application: simple machine
  • Maximum Horse Power Rating: 0.5 hp, 3 phase 230 V || 0.5 hp, 3 phase 460 V || 1.5 hp, 3 phase 460 V
  • Device Short Name: ATS01

Contractual warranty

  • Warranty: 18 months

Complementary

  • Electrical Connection: cage type connector – rigid 1 2.5 mm AWG 14 control circuit || cage type connector – flexible with cable end 2 0.75 mm AWG 18 power circuit || cage type connector – flexible without cable end 2 1 mm AWG 17 control circuit || cage type connector – flexible without cable end 2 1 mm AWG 17 power circuit || cage type connector – rigid 1 2.5 mm AWG 14 power circuit || cage type connector – rigid 2 1 mm AWG 17 control circuit || cage type connector – rigid 2 1 mm AWG 17 power circuit || cage type connector – flexible with cable end 1 2.5 mm AWG 14 control circuit || cage type connector – flexible with cable end 1 2.5 mm AWG 14 power circuit || cage type connector – flexible without cable end 1 2.5 mm AWG 14 control circuit || cage type connector – flexible without cable end 1 2.5 mm AWG 14 power circuit || cage type connector – flexible with cable end 2 0.75 mm AWG 18 control circuit
  • Network Frequency: 47.5…63 Hz
  • [Uc] Control Circuit Voltage: 110 V AC +/- 10 % 30 mA || 24 V AC/DC +/- 10 % 25 mA || 240 V AC +/- 10 % 65 mA
  • Height: 100 mm
  • Marking: CE
  • Power Range: 0-0.5 kW 200-240 V 1 phase || 0-0.5 kW 200-240 V 3 phase || 0.55-1 kW 200-240 V 3 phase || 1.1-2 kW 380-440 V 3 phase
  • Net Weight: 0.16 kg
  • Discrete Output Current: 2 A DC-13 || 3 A AC-15
  • Motor Starter Type: soft starter
  • Function Available: integrated bypass
  • Supply Voltage Limits: 99-528 V
  • Starting Time: 1 s / 100 || 5 s / 20 || adjustable from 1 to 5 s
  • Assembly Style: with heat sink
  • Compatibility Code: ATS01N1
  • Output Voltage: <= power supply voltage
  • Operating Position: vertical +/- 10 degree
  • Width: 23 mm
  • Depth: 100 mm
  • Starting Torque: 30…80 % of starting torque of motor connected directly on the line supply
  • Tightening Torque: 0.8-0.8 N.m
  • Supply Frequency: 50…60 Hz – 5…5 %

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Toxic Heavy Metal Free: Yes
  • Reach Regulation: Free of Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Reach Free Of Svhc: Yes
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: X
  • Circularity Profile: ENVEOLI100217EN
  • Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Environment

  • Product Certifications: CSA || GOST || C-tick || UL || CCC || B44.1-96/ASME A17.5 for starter wired to the motor delta terminal
  • Standards: EN/IEC 60947-4-2
  • Electromagnetic Compatibility: conducted and radiated emissions level B CISPR 11 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 || micro-cuts and voltage fluctuation IEC 61000-4-11 || voltage/current impulse level 3 IEC 61000-4-5 || conducted and radiated emissions level B IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || EMC immunity EN 50082-1 || EMC immunity EN 50082-2 || harmonics IEC 1000-3-2 || harmonics IEC 1000-3-4 || immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6
  • Ambient Air Temperature For Operation: -10-40 C without derating) || 40-50 C with current derating of 2 % per C)
  • Shock Resistance: 15 gn 11 ms EN/IEC 60068-2-27
  • Vibration Resistance: 1 gn 13-150 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz)EN/IEC 60068-2-6
  • Pollution Degree: 2 EN/IEC 60947-4-2
  • Ambient Air Temperature For Storage: -25-70 C EN/IEC 60947-4-2
  • Relative Humidity: 5-95 % without condensation or dripping water EN/IEC 60068-2-3
  • Ip Degree Of Protection: IP20
  • Operating Altitude: <= 3280.84 ft (1000 m) without derating || > 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m

Downloads

Spec Sheet

CAD

ATS01N103FT_CAD_DOC – ATS01N103FT_3D (stp)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTT (dxf)
ATS01N103FT_CAD_DOC – ATS01N103FT_2D+Right+Side+View (dwg)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTT (dwg)
ATS01N103FT_CAD_DOC – ATS01N103FT_2D+Front+View (dxf)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTA (dxf)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTF (dxf)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTR (dwg)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTF (dwg)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTA (dwg)
ATS01N103FT_CAD_DOC – ATS01N103FT_2D+Right+Side+View (dxf)
ATS01N103FT_CAD_DOC – ATS01N103FT_2D+Front+View (dwg)
Soft starter Power : 0.37 to 0.75 kW – U Single phase = 110 to 230 V or U 3-phase = 200 to 480 V – ATS01N103FTR (dxf)

Catalog

Altistart 01 Soft Starters Catalog – ATS01eCatalog (pdf)
Catalog: Soft starters Altistart 01 – DIA2ED2140603EN (pdf)
Automation and Control Essentials Catalog 2023-EN – DIA5ED2170101EN_v7_Web (pdf)
Industrial Control Panel Solutions Catalog – 8800CT1801 (pdf)

Handout

Altistart 01 AC Soft Starters Handout – 8800HO1303_Altistart01 (pdf)

Certificate

E184727 UL GENERIC CERTIFICATES – E184727+UL+CERTIFICATES (pdf)
ATS01 CSA CERTIFICATE – CoFC_80071573_EN (pdf)
ATS01 CCC CERTIFICATE 3-3 – 2015010304751607 (pdf)
ATS01 CSA Certificate of Compliance – COFC_80094867_EN (pdf)

Instruction sheet

Instruction Sheet – ATS01N1…FT – ATS01_IS_ATS01N1–FT_1624685_07 (pdf)

Technical Drawing

ATS01N103FT_2D_Drwng_PDF – ATS01N103FT_2D+Sales+Drawing (pdf)

Declaration of conformity

ATS01 EU DECLARATION – IA_ATS01_-_EU_Declaration_2021-09.docx (pdf)
ATS01N103-106FT_CCC_SDOC_PE – CCC+SDoC_ATS01N103FT+to+ATS01N106FT_2020980304001804+-+CQC2015010304751607_CN (pdf)
ATS01_UK_DECLARATION – UK_ATS01_-_UK_Declaration_2021-09.docx (pdf)
ATS01 C-TICK certificate of conformity – ATS01+C-TICK+certificate+of+conformity (pdf)

Circularity Profile

ALTISTART 01, 0.75 15 kW, Product End-of-Life Instructions – ENVEOLI100217EN_V0 (pdf)

Add a Review