Shopping Cart

TeSys Deca, thermal overload relay, 2.5 to 4 A, class 10A

Original price was: $53.40.Current price is: $26.70.


Specifications Network Type: AC || DC Thermal Protection Adjustment Range: 2.5-4 A Relay Application: motor protection Product Or Component Type: differential thermal overload relay Product...



Specifications

  • Network Type: AC || DC
  • Thermal Protection Adjustment Range: 2.5-4 A
  • Relay Application: motor protection
  • Product Or Component Type: differential thermal overload relay
  • Product Name: TeSys LRD || TeSys Deca
  • Thermal Overload Class: class 10A IEC 60947-4-1
  • Range: TeSys || TeSys Deca
  • [Ui] Rated Insulation Voltage: power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
  • Product Compatibility: LC1D12 || LC1D09 || LC1D25 || LC1D38 || LC1D32 || LC1D18
  • Device Short Name: LRD

Contractual warranty

  • Warranty: 18 months

Complementary

  • Network Frequency: 0…400 Hz
  • Height: 66 mm
  • [Ith] Conventional Free Air Thermal Current: 5 A signalling circuit
  • Auxiliary Contact Composition: 1 NO + 1 NC
  • Connections – Terminals: control circuit screw clamp terminals 2 1-2.5 mm flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm flexible without cable end || power circuit screw clamp terminals 1 1-4 mm flexible with cable end || power circuit screw clamp terminals 1 1-6 mm solid without cable end
  • Phase Failure Sensitivity: tripping current 130 % of Ir on two phase, the last one at 0
  • [Ue] Rated Operational Voltage: 690 V AC 0…400 Hz power circuit IEC 60947-4-1
  • Associated Fuse Rating: 4 A gG signalling circuit || 4 A BS signalling circuit
  • Net Weight: 0.124 kg
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV
  • Permissible Current: 3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit
  • Tripping Threshold: 1.14 +/- 0.06 Ir IEC 60947-4-1
  • Tightening Torque: control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
  • Control Type: Red push-button stop || Blue push-button reset
  • Mounting Support: plate, with specific accessories || rail, with specific accessories || under contactor
  • Width: 45 mm
  • Depth: 70 mm
  • Temperature Compensation: -20-60 C

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP080206EN
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI0802006
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: IEC || UL || CSA || CCC || EAC || BV || RINA || DNV-GL || LROS (Lloyds register of shipping) || ATEX INERIS || UKCA
  • Mechanical Robustness: vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
  • Standards: EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5 || EN 50495
  • Climatic Withstand: IACS E10
  • Ambient Air Temperature For Operation: -20-60 C without derating IEC 60947-4-1
  • Dielectric Strength: 1.89 kV 50 Hz IEC 60947-1
  • Ip Degree Of Protection: IP20 conforming to IEC 60529
  • Flame Retardance: V1 conforming to UL 94
  • Ambient Air Temperature For Storage: -60-70 C

Downloads

Spec Sheet

Catalog

TeSys contactors for railway applications- Catalogue 2022 – LVCATRAIL_EN+(web) (pdf)
Digest Catalog 18: Contactors and Starters-IEC (SEP 2022) – 0100CT1901_SEC-18_SEP2022 (pdf)
Digest Catalog 16: NEMA and Definite Purpose Contactors and Starters (SEP 2022) – 0100CT1901_SEC-16_SEP2022 (pdf)
Automation and Control Essentials Catalog 2023-EN – DIA5ED2170101EN_v7_Web (pdf)
Altistart 01 Soft Starters Catalog – ATS01eCatalog (pdf)
Industrial Control Panel Solutions Catalog – 8800CT1801 (pdf)
TeSys Catalogue – 2022 – Chapter B11 – Overload relays TeSys LRK, Deca, Giga, RM1, LT3 – B11+-+Overload+relays_EN+(web) (pdf)

CAD

TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-right (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-bottom (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-top (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-bottom (dxf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675 (pdf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-back (dxf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-isometric (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-right (dxf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-left (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-back (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-isometric (dxf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-top (dxf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-left (dxf)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_3D-simplified (stp)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-front (dwg)
TeSys LR.D – TeSys_THERMAL RELAY – 3D CAD – MCADPD0004675_2D-front (dxf)

Instruction sheet

LRD – Instruction Sheet – 164552301A50-16 (pdf)
LRD, LR3D – Thermal overload relay up to 15 kW (instruction sheet printed on the box)_Instruction sheet – 1645523_01A55-11 (pdf)
AC Magnetic Starters, Class 8536 Type SA, Form E, Series C, Size 00, 2- and 3-Poles Installation Instructions – 30072-454-65 (pdf)
AC Magnetic Starters, Class 8536 Type SB, Form E, Series C, Size 0, 2- and 3-Poles – Installation Instructions – 30072-454-66 (pdf)

Brochure

TeSys Refresh Informational Guide – Brochure – 998-20803955_GMA-US (pdf)
Industrial Automation and Control Product Lines Brochure – 998-20256927_2019_Line_Card_GM (pdf)
Square D Model 6 Intelligent Motor Control Centers Brochure – 8998BR0001 (pdf)

Certificate

UL_Certificate_TeSys D_LRD01-35&LR3D01-35 – E39281-20001012-CertificateofCompliance (pdf)
CB Certificate TeSys D – LRD01-35&LR3D01-35_Bangpoo – CB_LRD01-35_LR3D01-35_Bp_FR_707024 (pdf)
DNV Type Approval Certificate_TeSys D_LRD01-35_LRD33-43_LAD7 – LRD01-35_LRD33-43_LAD7_TAE00001M6-revision1 (pdf)
BV Type Approval Certificate_TeSys D_LRD01-35&LR3D01-35 – LRD01-35_LAD7_19412_C0_BV (pdf)
UL Certificate 164353, ABL7UPS, UES – NKCR.E164353+-+Auxiliary+Devices (pdf)
CSA Certificate_ TeSys D_LRD01-35&LR3D01-35&LRD04-32L&LR3D04-32L – LRD01-35_LR3D01-35_COFC_80156162_EN (pdf)
Marine_Certificate_TeSys D_LRD01-35&LR3D01-35 – LRD01-35_LR3D01-35_LAD7_cLR22413629TA+with+app-1662184-Schneider+Electric+Industries (pdf)
RINA Type Approval Certificate_TeSys D_LRD01-35&LR3D01-35 – LRD01-35_ELE151421CS (pdf)
ATEX_Certificate_TeSys D_LRD01-35_LRD04L-32L – LRD01-35_LRD04L-32L_06ATEX0036X.02 (pdf)
CB Certificate TeSys D – LRD01-35&LR3D01-35_Dijon – CB_LRD01-35_LR3D01-35__Dj_FR_707035 (pdf)

Circularity Profile

TeSys Deca overload relay – EoLI_ENVEOLI0802006_V2 (pdf)

User guide

TeSys Protect – Deca Overload Relays (0.1 to 38 A) – Use in Explosive Atmospheres – 1672545-07 (pdf)

Environmental Disclosure

TeSys Deca overload relay – Internal+PEP+ENVPEP080206EN_V2 (pdf)

Declaration of conformity

UKCA Declaration TeSysD_LRD01-35_LRD04L-32L_LAD7B106 – UK_Doc_LRD01-35_LR3D01-35_SC16031603-UK.docx (pdf)

Videos

Mounting a TeSys D-Line Contactor with Everlink Terminals to a Panel | Schneider Electric Support Removing Everlink Terminals from TeSys D Series Contactors | Schneider Electric Support Mounting LRD Overload Relay to TeSys D Series Contactor | Schneider Electric Support Locating Complete Part Number on Telemecanique LR2D Overload Relays | Schneider Electric Support

Add a Review

Your email address will not be published. Required fields are marked *

Related Products